 The more the merrier

Having lots of power points is great – it is so much better and safer than using extension plug-in boards. Plugging too many things into a single power point can cause it to become overloaded – which might even lead to fires in the case of permanently plugged-in equipment.

Where power points are installed will differ from house to house, but in most cases the locations for your power points will be pretty much a foregone conclusion, provided that your house has been planned in a way that assumes certain areas will be used in certain ways. When in doubt, if you have the option to it’s always favorable to install more power points than to have not enough.

Having lots of power points comes at a small cost though. Not only are you paying for more ‘bakelite’ (the charming, old fashioned term for switches and power points) you will also need to extend your switchboard with more miniature circuit breakers (MCBs) and Safety switches (RCD`s), and additional wiring. Either way, it’s always cheaper to overcompensate when you’re building than to try and add new power points to an existing home but we all know how hard it is to imagine yourself in 5-10 years time and what you will need then.

How many power points per circuit?

A circuit is a single cable supplying power points (also called GPOs – general power outlets) in your home. The circuit is connected to (and protected by) an MCB. There are basic rules about how much current will be used in a single circuit based on the number of GPOs it feeds.

To take a practical example: 20 GPOs, each rated at 10 amps (in practice this is 10 points each with two sockets) are assessed by the wiring rules as likely to need a maximum current draw of 10 amps. The assumption is that they will not all be used simultaneously – and won’t necessarily be connected to appliances drawing 10 amps.

A typical modern home with three bedrooms will have in excess of 40 individual power points. By the wiring rules, that is assessed as a total current load of 15 amps (10 amps for the first 20 GPOs plus 5 amps for the next 20).

The sensible plan

Extending installations can be expensive, for a couple of reasons:

  • The current carrying capacity of the wiring to your power points may not be sufficient if you are adding lots more power points, in which an additional circuit maybe required back to the switchboard.
  • You may need an extra circuit breaker or additional safety switch if the maximum of 3 circuits per safety switch has been reached to allow for the extra power circuit, for which you may not have room in your switchboard. This will add to the expense by requiring you to get a switchboard upgrade or sometimes where possible change your current double module safety switches to individual breaker/safety switch single module combinations to free up some extra room.
  • Your current installation may not be protected by a safety switch at all and if additional work is to be carried out of installing additional power points then this would have to be brought up to current day standards and safety switch protected added to that circuit.

Our electricians see all these scenarios on a daily basis and can very quickly point you in the right direction for what is required in your specific circumstances for any work you maybe planning for the future.